{"product_id":"supertack-hybrid-titanium-gbr-fixation-tacks","title":"SuperTack Fixation Tacks – Titanium GBR (3mm, 4mm, 5mm)","description":"\u003cp data-start=\"97\" data-end=\"449\"\u003eSuperTack fixation tacks are precision-engineered titanium pins designed for secure fixation of membranes, meshes, and cortical plates during Guided Bone Regeneration (GBR) procedures. Manufactured from implant-grade Ti-6Al-4V (Ti Gr5) titanium certified to ASTM F136, SuperTack tacks deliver high primary stability with controlled, atraumatic removal.\u003c\/p\u003e\n\u003cp data-start=\"451\" data-end=\"779\"\u003eA defining feature of the SuperTack system is its unique head geometry. The 2.5 mm diameter tack head features a flat-bottom design that ensures uniform, stable compression of the membrane or mesh against bone, regardless of material type. This geometry provides a tight, reliable grip without tearing or deforming the membrane.\u003c\/p\u003e\n\u003cp data-start=\"781\" data-end=\"1149\"\u003eTraditionally, PTFE and titanium-reinforced membranes require fixation screws rather than tacks. SuperTack is the first hybrid fixation system designed to securely fixate resorbable membranes, non-resorbable PTFE-Ti membranes, titanium mesh, and cortical plates using a single tack-based system—eliminating the need to switch fixation methods based on material choice.\u003c\/p\u003e\n\u003cp data-start=\"1151\" data-end=\"1472\"\u003eThe tack shaft is tapered to allow easy insertion into cancellous and hard cortical bone while enabling predictable removal after healing. The blue surface coloration is achieved through titanium anodization—not dyes—creating a biocompatible titanium oxide layer that improves visibility under soft tissue during removal.\u003c\/p\u003e\n\u003cp data-start=\"1474\" data-end=\"1608\"\u003eAll SuperTack tacks are plasma surface cleaned, packaged in a cleanroom environment, and supplied sterile via gamma-ray sterilization.\u003c\/p\u003e\n\u003chr data-start=\"1610\" data-end=\"1613\"\u003e\n\u003ch3 data-start=\"1615\" data-end=\"1647\"\u003eClinical Indications by Size\u003c\/h3\u003e\n\u003cp data-start=\"1649\" data-end=\"1751\"\u003e\u003cstrong data-start=\"1649\" data-end=\"1662\"\u003e3 mm Tack\u003c\/strong\u003e\u003cbr data-start=\"1662\" data-end=\"1665\"\u003eIndicated for fixation of collagen membranes in GBR procedures.\u003cbr data-start=\"1728\" data-end=\"1731\"\u003eAvailable packaging:\u003c\/p\u003e\n\u003cul data-start=\"1752\" data-end=\"1774\"\u003e\n\u003cli data-start=\"1752\" data-end=\"1762\"\u003e\n\u003cp data-start=\"1754\" data-end=\"1762\"\u003e5-pack\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1763\" data-end=\"1774\"\u003e\n\u003cp data-start=\"1765\" data-end=\"1774\"\u003e10-pack\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1776\" data-end=\"1818\"\u003e\u003cstrong data-start=\"1776\" data-end=\"1789\"\u003e4 mm Tack\u003c\/strong\u003e\u003cbr data-start=\"1789\" data-end=\"1792\"\u003eIndicated for fixation of:\u003c\/p\u003e\n\u003cul data-start=\"1819\" data-end=\"1910\"\u003e\n\u003cli data-start=\"1819\" data-end=\"1840\"\u003e\n\u003cp data-start=\"1821\" data-end=\"1840\"\u003ePTFE-Ti membranes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1841\" data-end=\"1860\"\u003e\n\u003cp data-start=\"1843\" data-end=\"1860\"\u003eCortical plates\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1861\" data-end=\"1899\"\u003e\n\u003cp data-start=\"1863\" data-end=\"1899\"\u003eTitanium mesh\u003cbr data-start=\"1876\" data-end=\"1879\"\u003eAvailable packaging:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1900\" data-end=\"1910\"\u003e\n\u003cp data-start=\"1902\" data-end=\"1910\"\u003e5-pack\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1912\" data-end=\"1954\"\u003e\u003cstrong data-start=\"1912\" data-end=\"1925\"\u003e5 mm Tack\u003c\/strong\u003e\u003cbr data-start=\"1925\" data-end=\"1928\"\u003eIndicated for fixation of:\u003c\/p\u003e\n\u003cul data-start=\"1955\" data-end=\"2065\"\u003e\n\u003cli data-start=\"1955\" data-end=\"1982\"\u003e\n\u003cp data-start=\"1957\" data-end=\"1982\"\u003eThicker cortical plates\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1983\" data-end=\"2005\"\u003e\n\u003cp data-start=\"1985\" data-end=\"2005\"\u003eCortical laminates\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2006\" data-end=\"2054\"\u003e\n\u003cp data-start=\"2008\" data-end=\"2054\"\u003eDense bone applications\u003cbr data-start=\"2031\" data-end=\"2034\"\u003eAvailable packaging:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2055\" data-end=\"2065\"\u003e\n\u003cp data-start=\"2057\" data-end=\"2065\"\u003e5-pack\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2067\" data-end=\"2129\"\u003e\u003cem data-start=\"2067\" data-end=\"2129\"\u003eThe millimeter designation refers to the length of the tack.\u003c\/em\u003e\u003c\/p\u003e\n\u003chr data-start=\"2131\" data-end=\"2134\"\u003e\n\u003ch3 data-start=\"2136\" data-end=\"2163\"\u003eKey Features \u0026amp; Benefits\u003c\/h3\u003e\n\u003cul data-start=\"2164\" data-end=\"2786\"\u003e\n\u003cli data-start=\"2164\" data-end=\"2232\"\u003e\n\u003cp data-start=\"2166\" data-end=\"2232\"\u003eUnique flat-bottom head geometry for secure membrane compression\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2233\" data-end=\"2306\"\u003e\n\u003cp data-start=\"2235\" data-end=\"2306\"\u003eHybrid fixation system suitable for all common GBR membrane materials\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2307\" data-end=\"2362\"\u003e\n\u003cp data-start=\"2309\" data-end=\"2362\"\u003eImplant-grade Ti Gr5 titanium (ASTM F136 compliant)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2363\" data-end=\"2413\"\u003e\n\u003cp data-start=\"2365\" data-end=\"2413\"\u003e2.5 mm head diameter for stable immobilization\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2414\" data-end=\"2479\"\u003e\n\u003cp data-start=\"2416\" data-end=\"2479\"\u003eTapered shaft for controlled insertion and atraumatic removal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2480\" data-end=\"2547\"\u003e\n\u003cp data-start=\"2482\" data-end=\"2547\"\u003eBlue anodized surface for enhanced visibility under soft tissue\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2548\" data-end=\"2614\"\u003e\n\u003cp data-start=\"2550\" data-end=\"2614\"\u003eNo dyes or coatings; surface consists solely of titanium oxide\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2615\" data-end=\"2665\"\u003e\n\u003cp data-start=\"2617\" data-end=\"2665\"\u003eEffective in cancellous and hard cortical bone\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2666\" data-end=\"2732\"\u003e\n\u003cp data-start=\"2668\" data-end=\"2732\"\u003eNo mandatory removal timeline; safe for long-term implantation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2733\" data-end=\"2786\"\u003e\n\u003cp data-start=\"2735\" data-end=\"2786\"\u003eSterile, cleanroom packaged, gamma-ray sterilized\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2788\" data-end=\"2791\"\u003e\n\u003ch3 data-start=\"2793\" data-end=\"2824\"\u003eMaterial \u0026amp; Biocompatibility\u003c\/h3\u003e\n\u003cp data-start=\"2825\" data-end=\"3191\"\u003eSuperTack tacks are manufactured from Ti Gr5 titanium alloy certified to ASTM F136, the established standard for implantable medical devices. Although Ti Gr5 is an alloy, it is fully biocompatible and widely used in dental and orthopedic implantology. The anodized blue coloration results from controlled oxide layer formation and contains no dyes or toxic elements.\u003c\/p\u003e\n\u003chr data-start=\"3193\" data-end=\"3196\"\u003e\n\u003ch3 data-start=\"3198\" data-end=\"3209\"\u003eRemoval\u003c\/h3\u003e\n\u003cp data-start=\"3210\" data-end=\"3613\"\u003eTacks may be removed once the bone graft has fully healed. Removal requires only a minimal incision, allowing the tapered tack to be gently slid out. There is no time limitation for removal, as the titanium material is approved for permanent implantation. For anterior and lingual access, a dedicated lingual applicator is available to facilitate placement and retrieval in challenging anatomical areas.\u003c\/p\u003e\n\u003chr data-start=\"3615\" data-end=\"3618\"\u003e\n\u003ch3 data-start=\"3620\" data-end=\"3642\"\u003eAvailable Variants\u003c\/h3\u003e\n\u003cul data-start=\"3643\" data-end=\"3715\"\u003e\n\u003cli data-start=\"3643\" data-end=\"3660\"\u003e\n\u003cp data-start=\"3645\" data-end=\"3660\"\u003e3 mm – 5-pack\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3661\" data-end=\"3679\"\u003e\n\u003cp data-start=\"3663\" data-end=\"3679\"\u003e3 mm – 10-pack\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3680\" data-end=\"3697\"\u003e\n\u003cp data-start=\"3682\" data-end=\"3697\"\u003e4 mm – 5-pack\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3698\" data-end=\"3715\"\u003e\n\u003cp data-start=\"3700\" data-end=\"3715\"\u003e5 mm – 5-pack\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"McBio","offers":[{"title":"3mm \/ 5 tacks","offer_id":46636187156657,"sku":"ELI-9514010-5","price":109.99,"currency_code":"USD","in_stock":true},{"title":"3mm \/ 10 tacks","offer_id":46636187189425,"sku":"ELI-9514010-10","price":199.99,"currency_code":"USD","in_stock":true},{"title":"4mm \/ 5 tacks","offer_id":46636187222193,"sku":"ELI-9514014-5","price":119.99,"currency_code":"USD","in_stock":true},{"title":"5mm \/ 5 tacks","offer_id":46636187287729,"sku":"ELI-9514020-5","price":119.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0687\/5915\/8961\/files\/Tack3mm.jpg?v=1771789376","url":"https:\/\/www.xemax.com\/products\/supertack-hybrid-titanium-gbr-fixation-tacks","provider":"Xemax Surgical Products, Inc.","version":"1.0","type":"link"}