{"product_id":"piezomed-extraction-tips","title":"W\u0026H Piezomed Extraction Tips","description":"\u003ch3 data-start=\"291\" data-end=\"313\"\u003eProduct Overview\u003c\/h3\u003e\n\u003cp data-start=\"314\" data-end=\"479\"\u003ePiezomed extraction tips from \u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eW\u0026amp;H Dentalwerk\u003c\/span\u003e\u003c\/span\u003e are specifically designed for atraumatic tooth extraction with preservation of the alveolar bone.\u003c\/p\u003e\n\u003cp data-start=\"481\" data-end=\"860\"\u003eUsing piezoelectric ultrasound technology, these tips enable controlled detachment of the periodontium while minimizing trauma to surrounding hard and soft tissues. When a piezo instrument is inserted, the Piezomed system automatically recognizes the tip and assigns the appropriate power class, ensuring optimal working conditions, procedural safety, and consistent performance.\u003c\/p\u003e\n\u003chr data-start=\"862\" data-end=\"865\"\u003e\n\u003ch2 data-start=\"867\" data-end=\"883\"\u003eIndications\u003c\/h2\u003e\n\u003cul data-start=\"884\" data-end=\"1014\"\u003e\n\u003cli data-start=\"884\" data-end=\"915\"\u003e\n\u003cp data-start=\"886\" data-end=\"915\"\u003eAtraumatic tooth extraction\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"916\" data-end=\"951\"\u003e\n\u003cp data-start=\"918\" data-end=\"951\"\u003ePeriodontal ligament detachment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"952\" data-end=\"1014\"\u003e\n\u003cp data-start=\"954\" data-end=\"1014\"\u003ePreservation of alveolar bone for future implant placement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1016\" data-end=\"1019\"\u003e\n\u003ch2 data-start=\"1021\" data-end=\"1058\"\u003eTip Selection and Clinical Roles\u003c\/h2\u003e\n\u003ch3 data-start=\"1060\" data-end=\"1095\"\u003ePeriodontal Ligament Detachment\u003c\/h3\u003e\n\u003cp data-start=\"1097\" data-end=\"1213\"\u003e\u003cstrong data-start=\"1097\" data-end=\"1136\"\u003eEX1 Tip for Piezomed (REF 06069300)\u003c\/strong\u003e\u003cbr data-start=\"1136\" data-end=\"1139\"\u003eUltrasonic extraction tip for buccal and lingual \/ palatal applications.\u003c\/p\u003e\n\u003cul data-start=\"1214\" data-end=\"1551\"\u003e\n\u003cli data-start=\"1214\" data-end=\"1238\"\u003e\n\u003cp data-start=\"1216\" data-end=\"1238\"\u003e0.5 mm tip thickness\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1239\" data-end=\"1261\"\u003e\n\u003cp data-start=\"1241\" data-end=\"1261\"\u003e9 mm working depth\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1262\" data-end=\"1551\"\u003e\n\u003cp data-start=\"1264\" data-end=\"1551\"\u003eManufacturer-recommended settings: \u003cstrong data-start=\"1299\" data-end=\"1331\"\u003e100% power \/ 100% irrigation\u003c\/strong\u003e\u003cbr data-start=\"1331\" data-end=\"1334\"\u003eDesigned for detachment of the periodontium to facilitate atraumatic tooth extraction while preserving hard tissue. Best results are achieved with constant motion to ensure adequate cooling within the gingival sulcus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1553\" data-end=\"1556\"\u003e\n\u003cp data-start=\"1558\" data-end=\"1663\"\u003e\u003cstrong data-start=\"1558\" data-end=\"1597\"\u003eEX2 Tip for Piezomed (REF 06071100)\u003c\/strong\u003e\u003cbr data-start=\"1597\" data-end=\"1600\"\u003eUltrasonic extraction tip for mesial and distal applications.\u003c\/p\u003e\n\u003cul data-start=\"1664\" data-end=\"2027\"\u003e\n\u003cli data-start=\"1664\" data-end=\"1688\"\u003e\n\u003cp data-start=\"1666\" data-end=\"1688\"\u003e0.5 mm tip thickness\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1689\" data-end=\"1711\"\u003e\n\u003cp data-start=\"1691\" data-end=\"1711\"\u003e9 mm working depth\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1712\" data-end=\"2027\"\u003e\n\u003cp data-start=\"1714\" data-end=\"2027\"\u003eManufacturer-recommended settings: \u003cstrong data-start=\"1749\" data-end=\"1781\"\u003e100% power \/ 100% irrigation\u003c\/strong\u003e\u003cbr data-start=\"1781\" data-end=\"1784\"\u003eUsed for detachment of the periodontium in mesial and distal orientations, supporting controlled tooth extraction with preservation of the alveolar bone. Continuous movement is recommended to maintain sufficient cooling in the gingival sulcus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2029\" data-end=\"2032\"\u003e\n\u003ch2 data-start=\"2034\" data-end=\"2064\"\u003eTypical Clinical Workflow\u003c\/h2\u003e\n\u003cul data-start=\"2065\" data-end=\"2203\"\u003e\n\u003cli data-start=\"2065\" data-end=\"2139\"\u003e\n\u003cp data-start=\"2067\" data-end=\"2139\"\u003e\u003cstrong data-start=\"2067\" data-end=\"2074\"\u003eEX1\u003c\/strong\u003e – Buccal and lingual \/ palatal periodontal ligament detachment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2140\" data-end=\"2203\"\u003e\n\u003cp data-start=\"2142\" data-end=\"2203\"\u003e\u003cstrong data-start=\"2142\" data-end=\"2149\"\u003eEX2\u003c\/strong\u003e – Mesial and distal periodontal ligament detachment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2205\" data-end=\"2310\"\u003eUsed together, EX1 and EX2 allow circumferential ligament release for controlled, atraumatic extractions.\u003c\/p\u003e\n\u003chr data-start=\"2312\" data-end=\"2315\"\u003e\n\u003ch2 data-start=\"2317\" data-end=\"2342\"\u003eSystem Compatibility\u003c\/h2\u003e\n\u003cul data-start=\"2343\" data-end=\"2483\"\u003e\n\u003cli data-start=\"2343\" data-end=\"2419\"\u003e\n\u003cp data-start=\"2345\" data-end=\"2419\"\u003eDesigned exclusively for the \u003cstrong data-start=\"2374\" data-end=\"2417\"\u003eW\u0026amp;H Piezomed SA-320 Piezosurgery System\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2420\" data-end=\"2483\"\u003e\n\u003cp data-start=\"2422\" data-end=\"2483\"\u003eAutomatic instrument recognition and power-class adjustment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2485\" data-end=\"2488\"\u003e\n\u003ch2 data-start=\"2490\" data-end=\"2541\"\u003eWhy Clinicians Choose Piezomed for Extractions\u003c\/h2\u003e\n\u003cul data-start=\"2542\" data-end=\"2828\"\u003e\n\u003cli data-start=\"2542\" data-end=\"2599\"\u003e\n\u003cp data-start=\"2544\" data-end=\"2599\"\u003eAtraumatic ultrasonic periodontal ligament detachment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2600\" data-end=\"2660\"\u003e\n\u003cp data-start=\"2602\" data-end=\"2660\"\u003ePreservation of alveolar bone and surrounding structures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2661\" data-end=\"2727\"\u003e\n\u003cp data-start=\"2663\" data-end=\"2727\"\u003eImproved control compared to traditional extraction techniques\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2728\" data-end=\"2785\"\u003e\n\u003cp data-start=\"2730\" data-end=\"2785\"\u003eAutomatic power management for consistent performance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2786\" data-end=\"2828\"\u003e\n\u003cp data-start=\"2788\" data-end=\"2828\"\u003eSterilizable for repeated clinical use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"W\u0026H","offers":[{"title":"EX1","offer_id":46632062222513,"sku":"WH-06069300","price":267.99,"currency_code":"USD","in_stock":true},{"title":"EX2","offer_id":46632062058673,"sku":"WH-06071100","price":267.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0687\/5915\/8961\/files\/Instrument_EX1.jpg?v=1771789396","url":"https:\/\/www.xemax.com\/products\/piezomed-extraction-tips","provider":"Xemax Surgical Products, Inc.","version":"1.0","type":"link"}